Independent review for clinical AI

Find the failures your evals didn't catch, before hospitals do.

The independent, expert-led reliability risk audit of your clinical AI through evidence-based clinical assessment, adversarial testing and workflow x population specific benchmarking

See A Workflow Demo

Source note

Patient reports intermittent dizziness. No chest pain. No shortness of breath.

AI summary, checked by GoodHart

  • Dizziness reportedMatches "reports intermittent dizziness"supported
  • Chest pain reportedSource says "No chest pain"held
  • Breathing normalMatches "No shortness of breath"supported

1 of 3 claims contradicts the source. The note is held for review.

How We Evaluate

A comprehensive assurance partner for clinical AI.

Independent testing, clinical depth and hospital-ready evidence in one review.

  1. 01

    Clinical Failure-Mode Intel

    A growing bank of real-world failure modes, edge cases and adversarial scenarios across conditions, demographics and workflows.

  2. 02

    Adversarial Testing & Red-Teaming

    Stress-test your model with difficult, realistic and deliberately challenging clinical inputs (e.g. negation, attribution, conflict, missing context).

  3. 03

    Clinical Benchmarking & Rubrics

    Build workflow-specific evaluation rubrics, benchmark performance across scenarios and patient populations, and provide measurable findings.

  4. 04

    Hospital Readiness & Enterprise Support

    Bring our experience working with hospitals to help you anticipate procurement, clinical governance and AI evaluation questions.

The report, in action

What an assessment looks like

A synthetic example. Hover over the numbers and bars for detail, then scroll for the full report.

Example assessment

synthetic data · cross-vertical · illustrative

One clinical AI output can look right. The evidence can tell a different story.

A fluent, well-structured response is not necessarily a supported clinical response. The gap appears when claims are checked against the source, the patient they refer to, and the workflow in which they will be used.

The assessment question

What exactly did the AI claim, and what in the available evidence supports it?

We evaluated a synthetic set of 40 pre-declared scenarios across clinical documentation, summarisation, medication instructions, triage and decision-support workflows. Each scenario was run three times. The checks focused on whether the output preserved what the source actually said, including who it referred to, what was denied, what remained uncertain and what had not yet happened.

40

Pre-declared cases

Across multiple clinical workflows

120

Recorded runs

Three runs per case

24/40

Cases with a finding

At least one issue observed

31/120

Outputs flagged

One or more verification issues

Flagged outputs by pattern (illustrative)

  • Unsupported content8
  • Inconsistent repeat output7
  • Wrong subject attribution6
  • Omitted information5
  • Negation / uncertainty5

One output may contain more than one issue; these category counts should not be summed to infer the number of defective outputs.

Staying on this tab. Click another tab to continue.

All 12 findings, and what they mean.

Each finding describes a failure pattern that can arise across clinical AI products. The exact test criteria must be adapted to the product's intended use, input types, output format and downstream workflow.

CaseFindingSeverityObservedRepeat behaviour
Critical case 1Clinical information appears in the output without support in the sourceCritical6/40 casesIntermittent · 1–2/3 runs
Critical case 2Information about another person is assigned to the patientCritical2/2 casesAlways · 6/6 runs
High case 1Identical input returns materially different answersHigh9/40 casesIntermittent
High case 2A denied symptom or condition is presented as presentHigh3/8 casesAlways in tested examples
High case 3A medication name, dose, unit, route or frequency is changedHigh2/5 casesAlways in tested examples
High case 4A relevant finding or qualifier stated in the source is omittedHigh5/40 casesIntermittent
Medium case 1A planned or future event is described as completed or currentMedium2/4 casesIntermittent
Medium case 2Uncertainty or qualification is removed from the source statementMedium3/6 casesAlways in tested examples
Medium case 3Location, laterality or relationship between findings is misreadMedium1/3 casesAlways in tested examples
Medium case 4Older information is used despite a newer conflicting entryMedium2/5 casesIntermittent
Low case 1Irrelevant or administrative text produces a clinical findingLow1/6 casesIntermittent
Low case 2An escalation or priority is generated without support in input or rulesLow1/4 casesIntermittent

Book a review